PHGFREN=DISABLED, SSEL=NORMAL, PUGFREN=DISABLED
Module Configuration
COUNT | Pulse Generator Counter. |
SSEL | Speed Select. 0 (NORMAL): The SSG module runs at normal speed, where each pulse and phase cycle consists of 16 ADC clocks. 1 (DOUBLE): The SSG module runs at double speed, where each pulse and phase cycle consists of 8 ADC clocks. |
PHGFREN | Phase Generator Free-Run Enable. 0 (DISABLED): The Phase Generator runs only when pulse generation occurs. 1 (ENABLED): The Phase Generator runs when an ADC is enabled, regardless of the Pulse Generator settings. |